College Pliers
Coller-Crile Artery Forceps
Coller-Crile Artery Forceps
delicate pattern
Coller-Crile Artery Forceps feature a delicate pattern with long, serrated jaws that can be used in general procedures. Largely used as a hemostatic agent to cease blood flow in vessels, they may also be used to grab and maneuver delicate tissues. Please note that website images are often representative of the product family and may not conform to the exact specifications or features of the item you select. The final specifications will match the description of the specific catalog item you select.
Collier Needle Holder
Collier Needle Holder
fenestrated jaws, 5-1/8" (13.0 cm)
Collier Needle Holder is handcrafted from surgical grade German stainless steel. Designed with fenestrated jaws and a ratcheted handle lock, this instrument holds the needle while suturing, while the fenestration allows for better management of the suture. This instrument is protected by Instruments 4 Dotors manufacturer warranty on defects in materials and workmanship.
Collin Abdominal Retractor
Set includes: frame (110.0 mm spread, 9-1/4" (23.5 cm)) & pair of blades (62.0 x 38.0 mm)
Collin Abdominal Retractor is an entire set that includes a frame and a pair of blades. These blades are outwardly curved at a right angle and are deep enough to retract thicker areas of the abdomen. In addition, the retractor contains ring handles and a spreader that has a maximum spread of 110.0 mm, which can keep larger incisions open.
Collin Pelvimeter
graduated in centimeters & inches, 13-3/4" (35.0 cm)?Collin Pelvimeter is commonly used in obstetrics and gynecology to assess the size of the female pelvis in relation to childbirth to determine if cesarean section is necessary. The pelvimeter features two flat arms to grasp the pelvis and a ruler at the hinge graduated in centimeters and inches. Please note that website images are often representative of the product family and may not conform to the exact specifications or features of the item you select. The final specifications will match the description of the specific catalog item you select.
Collin Retractor
Collin Retractor
double-ended, set of 2, 6-1/2" (16.5 cm)
Collin Retractor is designed to push back tissue that may conceal part of the area that is being operated on. With the help of the rounded double-ended blades on each end, damage to tissues is reduced while they are held firmly in the desired position. Depending on the size of the incision, this retractor comes in a set of two.
Collin Vaginal Speculum
Collin Vaginal Speculum features two blades at the end of a screw mechanism to keep the blades open in the vaginal canal for visualization and/or operative purposes. The instrument is available in various sized blades to accommodate a wide range of cases. Made of stainless steel for easy sterilization.
Collins Tissue Seizing Forceps
Jaws 12.0 mm wide, 6" (15.0 cm)
Collins Tissue Seizing Forceps is 6" in length and is ideally used in general surgery to obtain a firm grasp of tissues while an operation is being performed on nearby organs or tissues. The tips of the jaws are triangular in shape and are 12.0 mm wide. These tips also contain small teeth on the edge to minimize the possibility of slippage.
Cone Skull Punch
9-1/2" (24.0 cm)?Cone Skull Punch is ideally suited for use in a variety of neurosurgical procedures. It is specifically intended for use in punching holes through the patient's skull to allow access and fixation of bone flaps via the use of wires or other securing mechanisms. Additionally this punch can be used not only for the skull but also can be used in surgeries of the spinal column.
Cone Ventricular Needles
w/ 2 holes, luer lock hub, 3-1/2" (9.0 cm)?Cone Ventricular Needles are specialized needles designed for use specifically in the ventricles of the brain. They can be useful in a vast array of neurosurgical procedures of the brain such as craniotomies. This needle has two holes and has a leur lock hub. Additionally it is available in eight different sizes ranging from 12 gauge to 20 gauge making it possible to find a suitable size for whatever level of suction is necessary.