Name | Debakey Multi Purpose Peripheral Vascular Clamp |
Lead Time | Lead time advised within 48 hours of order placement. |
Specialty | Cardiothoracic-Cardiovascular Clamps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Lexis Industry |
Sterility | Non-Sterile |
Usage | Reusable |
Peripheral Vascular Clamp
Peripheral Vascular Clamp
3.0 cm long straight jaws, 8″ (20.0 cm)
DeBakey Multi-Purpose Peripheral Vascular Clamp is ideally crafted to be an all-purpose clamp for use during cardiothoracic surgical procedures to clamp peripheral vessels. This instrument is ideal for clamping any vessels during surgery for a number of reasons one of the most important being to occlude blood flow through vessels to prevent the patient from losing an excessive amount of blood. The slight angle of the blade allows the instrument handle to be slightly out of the surgical field so as to keep that as clear as possible for increased visibility.
61
People watching this product now!
SKU:
EI-04-1086
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Peripheral Vascular Clamp” Cancel reply
Related products
Cooley Cardiovascular Clamp – Fully-Curved
Fully-Curved
for temporary occulation of the iliac artery, 2-3/4" (7.0 cm) fully-curved jaws, 10-3/4" (27.3 cm)
Cooley Cardiovascular Clamp is ideally suited for use in cardiothoracic surgical procedures that require temporary occultation of the iliac artery. This instrument comes equipped with fully curved jaws making it particularly well suited for use in clamping vessels close to the diameter of the iliac vessels. The scissor grip handles and the ratcheting mechanism for keeping the clamp in place allows for this clamp to stay securely in place through the surgical procedure but is gentle enough to keep from injuring the vessel walls.
Cherry Supraceliac Clamp
Cherry Supraceliac Clamp
shanks curved 60 degrees, debakey 2x3 teeth, jaws 5-3/4", curved, 12-1/2" (31.0 cm)
Cheery Supraceliac Clamp is created to be of optimal use in cardiothoracic surgical procedures. This instrument is especially useful aortic aneurysm repairs of the abdominal and thoracic aorta particularly this clamp can be used in accessing the portion of the aorta that is found superior to the celiac artery. Curved shanks coupled with a 60 degree angle and DeBakey teeth allow this clamp to access some deeper vessel structures without damaging the vessel walls or the surrounding tissue.
Beck Vascular Clamp
Beck Vascular Clamp
cooley jaws calibrated at 5.0 mm intervals, straight shanks, 6" (15.0 cm)
Beck Vascular Clamp is suited for optimal use in cardiothoracic surgical procedures. This clamp is designed to clamp vessels and occlude blood flow during surgical procedures in many cases to prevent an excessive amount of blood loss from the patient. A unique feature of this clamp is the curved Cooley jaws that are calibrated at 50 mm intervals as well as the straight shanks. This instrument is available two sizes: small jaw with heavy curvature and large jaw with medium curvature.
Cooley Renal Artery Clamp
Cooley Renal Artery Clamp
Cooley Renal Artery clamp is ideally suited for use in cardiothoracic surgeries. The slightly curved shanks and angled jaws make this clamp perfect for its ideal use which is as a renal clamp to fully or partially cause occlusion of the renal vessels. These jaws are atraumatic thus reducing injury and stress to the vessel walls while still remaining firmly in their affixed location. This instrument is available in three sizes: 7.25", 7.5" and 10.75" to accommodate a number of different surgical approaches and surgeon preferences.
Cooley Anastomosis Clamp
Anastomosis Clamp
jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp is designed for use in cardiothoracic surgical procedures in which an anastomotic connection is to be formed between two vessels and blood flow needs to be reduce significantly via clamping. This instrument features jaws that are calibrated at 5 mm intervals making them ideally suited to give accurate measurement information during a surgical procedures. Additionally, this clamp features a slightly looped, u-shaped clamp to provide optimal gripping capacity but also maintaining that hold consistently throughout the procedure.
Cooley Multi Purpose Clamp
Cooley Multi Purpose Clamp
jaws angled 60 degrees
Cooley Multi Purpose Clamp is designed for use in a variety of cardiothoracic surgeries that require clamping of vessels. These multi-purpose clamps are uniquely designed to accommodate a number of different surgical maneuvers instead of being made for one specific purpose. The multiple application of this instrument making it a valuable tool in the operating room because it is suitable for most all clamping situations. Additionally, the jaws come angled at 60 degrees and this instrument is available in three different jaw lengths making it easy to find a suitable instrument for any surgical maneuver or surgeon preferences.
Cooley Pediatric Clamp
Cooley Pediatric Clamp
delicate clamp, jaws calibrated at 5.0 mm intervals, 5-1/2" (14.0 cm)
Cooley Pediatric Clamp is ideally suited for clamping in cardiothoracic surgical procedures with pediatric patients. This clamp features jaws that are calibrated at 5.0 mm intervals but are still delicate enough for use in pediatric surgeries. This instrument is designed to keep a firm hold on the vessels that are being occluded but delicate enough not to bruise or tear the vessels thus reducing the amount of damage done to the patient. This clamp is available in a number of different styles that include straight or angled shanks and straight, satinsky, angled, or spoon-shaped jaws making this instrument highly versatile and useful in the operating room.
Beck Miniature Aorta Clamp – Titanium
Titanium
straight shanks, 6-3/4" (17.0 cm), debakey jaws, titanium
Beck Miniature Aorta clamp is designed for use in cardiothoracic surgeries. This miniature aorta clamp is ideally suited for use in neonatal or pediatric patients who have vessels that are too small to be handled by traditional sized instruments. This instrument can be used to clamp the aorta to occlude blood flow and prevent excessive bleeding during surgery. Additionally, this clamp is available with either DeBakey jaws or titanium jaws.
Reviews
There are no reviews yet.