Name | Cooley Aorta Clamp |
Lead Time | Lead time advised within 48 hours of order placement. |
Specialty | Cardiothoracic-Cardiovascular Clamps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Lexis Industry |
Sterility | Non-Sterile |
Usage | Reusable |
Cooley Aorta Clamp
Cooley Aorta Clamp
Cooley Aorta Clamp is ideally suited for some cardiothoracic surgeries. This clamp is designed with a slight U-shaped hook shape to make a perfect tool for manipulation and clamping of the aorta. Additionally, these clamps are well suited for use in sectioning a specific portion of the aorta because they are created for easy handle a firm grip without causing any injury or damage to the vessel itself. This instrument is available in two different jaw lengths to make it suitable for use in a wide number of patients and surgeon preferences.
58
People watching this product now!
SKU:
EI-04-1016
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Cooley Aorta Clamp” Cancel reply
Related products
Cooley Acutely Curved Clamp
Cooley Acutely Curved Clamp
angled shanks, jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Acutely Curved Clamp is designed for use in cardiothoracic surgeries. This instrument is designed to clamp vessels to reduce or completely block blood flow during surgery to allow the procedure to continue in a certain anatomical location where the blood is no longer able to flow through. These clamps feature an angled shanks as well as jaws calibrate at 5 mm intervals. Additionally, this instrument is available in three sizes: small, medium and large to accommodate a variety of patient sizes and a the wide variety of vessels that this clamp can be used on.
Cooley Tangential Occlusion Clamp
Cooley Tangential Occlusion Clamp
double angled jaws calibrated at 5.0 mm intervals, 7-3/4" (19.5 cm)
Cooley Tangential Occlusion Clamp is uniquely designed to clamp vessels in a way that reduces blood flow without completely stopping it in cardiothoracic surgical procedures. This clamp can be best used when doing procedures such as side-by-side anastomosis that required some blood flow. Additionally, this instrument features double angled jaws that are calibrated at 5 mm intervals making it possible to make accurate measurements during the procedure.
Castaneda Clamp
Castaneda Clamp
curved shanks, long thin jaw, calibrated jaws, horizontal serrations, 6" (15.0 cm)
Cataneda Clamp is a versatile tool made for use in cardiothoracic surgical procedures for newborn babies. This clamps are designed for neonatal use and as much are much smaller than their traditional counterpart but are equally effective. This multipurpose clamp is designed with curved shanks as well as long thing calibrated jaws coupled with horizontal serrations. Additionally, this instrument is available at varying angles and as a multi purpose or partially occluding clamp making it easy to find a perfect fit for any surgical procedure.
Cooley Anastomosis Clamp Modified
Anastomosis Clamp Modified
30 degree side angled jaws, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp Modified is ideally used in cardiothoracic surgeries that require anastomosis between vessels and thus a clamp is utilized to reduce but not completely occlude blood flow. This instrument is hand-crafted by certified instrument makers to conform to the highest standards in instrumentation. Additionally, this modified anastomosis clamp features a 30 degree side angled jaw making it more able to access harder to reach vessels.
Cooley Aortic Aneurysm Clamp
Cooley Aortic Aneurysm Clamp
slightly curved jaws, jaws 7.6 cm, 10-3/4" (27.3 cm)
Cooley Aortic Aneurysm Clamp is made to be used cardiothoracic procedures that require clamping of the aorta, specifically at or around the site of aneurysm. This clamp can be used to in temporary occlusion of the aorta to resect fusiform aneurysms as well as provide additional support and stability in aortic grafting procedures. The slightly curved jaws gives this clamp the ability to contour to and seamlessly move through the surgical field causing the least amount of trauma to the aorta itself and surrounding tissue.
Cooley Cardiovascular Clamp – Fully-Curved
Fully-Curved
for temporary occulation of the iliac artery, 2-3/4" (7.0 cm) fully-curved jaws, 10-3/4" (27.3 cm)
Cooley Cardiovascular Clamp is ideally suited for use in cardiothoracic surgical procedures that require temporary occultation of the iliac artery. This instrument comes equipped with fully curved jaws making it particularly well suited for use in clamping vessels close to the diameter of the iliac vessels. The scissor grip handles and the ratcheting mechanism for keeping the clamp in place allows for this clamp to stay securely in place through the surgical procedure but is gentle enough to keep from injuring the vessel walls.
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp is a specialized piece of equipment designed for optimal use in cardiothoracic surgical procedures. This clamp is designed for use as a renal clamp to block or reduce blood flow through the renal vessels going to and from the kidney. To accommodate the positioning of these vessels this instrument comes with a significant angle to the jaws making access to the renal vasculature easier. This instrument is available angled either to the left or the right and also comes in either small or large jaws to accommodate a number of different patients sizes.
Cooley Occlusion Clamp
Cooley Occlusion Clamp
curved jaws, jaws 3.6 cm long
Cooley Occlusion Clamp is designed for use in cardiothoracic surgical procedures. This clamp can be used to clamp vessels to reduce or stop blood flow to prevent the patient from losing an excessive amount of blood. The jaws allow for firm grasp of the vessels but with reduced risk of crushing or bruising to the vessel wall. Additionally, this clamp features curved shanks and jaws giving them a contour more suitable for use in vascular surgical procedures. This instrument is available in two different lengths to accommodate different vessel sizes and positions.
Reviews