Name | Kielland Obstetrical Forceps |
Lead Time | 0-3 days |
Competitor | ;ET210R;GL55101;GL5510-1;510260;510-260;305671;30-5671;535060;53-5060;5350-60; |
Specialty | Obstetrics & Gynecology-Forceps – Obstetrical |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Lexis Industry |
Sterility | Non-Sterile |
Usage | Reusable |
Kielland Obstetrical Forceps
15-3/4″ (40.0 cm) ?Kielland Obstetrical Forceps feature a very small pelvic curve and a sliding lock to aid births where the fetal head is not in line with the birth canal. The small pelvic curve allows for rotation of the fetal head. The curved cephalic blades grasp the fetal head during delivery.
96
People watching this product now!
Description
Reviews (0)
Be the first to review “Kielland Obstetrical Forceps” Cancel reply
Related products
Colins Uterine Elevating Forceps
Fink Ovum Forceps
13.0 mm, concave tip, 10-1/2" (26.7 cm)?Fink Ovum Forceps are designed to properly remove placental tissue or other products of conception from the uterus. The hollow rectangular jaws feature serrated teeth to get a firm grasp on the tissue to be removed. The concave tip is designed to prevent grasping the fundus of the uterus.
Green-Armytage Uterine Forceps
8-3/4" (22.0 cm)?Green-Armytage Uterine Forceps are designed to grasp and clamp tissue in the uterus for removal or mobilization. The forceps feature locking ring handles and widened blades with grooves to provide a firm grip on the tissue. The forceps are available straight or angled to accommodate a wide range of cases.
Blumenthal Ovum Forceps
slightly curved, concave tip, 20.0 mm jaw, coarse teeth, 13" (33.0 cm) Blumenthal Ovum Forceps are ideal in the removal of placental tissue or other products of conception from the uterus to prevent infections. The hollow blades are slightly curved with coarse teeth on the jaws to firmly grasp the tissue to be removed. The concave tip is designed to prevent grasping the fundus of the uterus.
Dartigues Uterine Elevating Forceps
smooth jaws, straight, 10-1/4" (26.0 cm)?Dartigues Uterine Elevating Forceps are designed to remove tissue, tumors, or polyps from the uterus by elevating the vaginal wall. The clamps at the ends of the ring handles curve inward toward the handles. The clamps feature smooth jaws to firmly grasp the tissue to be removed.
Bierer Tenaculum
angled jaws, 5x6 teeth, 9" (22.9 cm) ?Bierer Tenaculum is commonly used in gynecology to stabilize a woman's cervix or uterus during a procedure. The tenaculum features angled jaws and inward facing hooks with 5X6 teeth to firmly grasp the tissue. The ring handles have a lock mechanism to hold the blades in various positions.
Reviews
There are no reviews yet.